All Stanbio Chemistry Reagents, Calibrators, Controls and Standards (A – Z)
The Stanbio Chemistry Reagents range includes liquid-stable reagents, calibrators, standards and controls that can be used on most main brand analyzers including Cobas, Architect, Dimension and Hitachi.
Stanbio Chemistry Reagents products are manufactured in our FDA regulated facility in Boerne, Texas. All stages of the Stanbio Chemistry Reagents manufacturing process are based on strict Current Good Manufacturing Practice regulations (cGMP). We also offer OEM and contract manufacturing services.
Our LiquiColor® and Liqui-UV® Stanbio Chemistry Reagents are designed for ease of use and maximum stability.
- Stability up to the expiration date, even after opening the bottle
- Ready to use liquid reagent
- Economical choice of reagent kits
- Avoid reconstitution errors and water contamination
All Stanbio Chemistry Reagents, Calibrators, Controls and Standards (A – Z)
Product | Ref no. | Type | Media | Methodology | Description of contents | Linearity | Read (nm) |
---|---|---|---|---|---|---|---|
Acetaminophen LiquiColor® test (Rate) | 2400-060 | Reagents | Liquid | Arylacylamidase/o-cresol | R1: 1 x 40 mL R2: 1 x 20 mL STD: 1 x 3 mL |
300 mg/L | 615 |
Albumin LiquiColor®test | 0285-500 | Reagents | Liquid | Bromocresol green reaction (BCG) | R: 2 x 250 mL STD: 1 x 3 mL |
7 g/dL | 550 |
Alkaline Phosphatase LiquiColor test (Rate) |
2900-430 | Reagents | Liquid | P-nitrophenylphosphate | R1: 4 x 25 mL R2: 1 x 20 mL |
800 U/L | 405 |
Alkaline Phosphatase LiquiColor test (Rate) |
2900-500 | Reagents | Liquid | P-nitrophenylphosphate | R1: 4 x 105 mL R2: 4 x 20 mL |
800 U/L | 405 |
Alpha-amylase LiquiColor® test | 2970-430 | Reagents | Liquid | EPS-G7 substrate | R: 4 x 30 mL | 2000 U/L | 405 |
ALT/ SGPT Liqui-UV® test (Rate) |
2930-430 | Reagents | Liquid | IFCC recommended procedure | R1: 4 x 25 mL R2: 1 x 20 mL |
600 U/L | 340 |
ALT/ SGPT Liqui-UV® test (Rate) |
2930-500 | Reagents | Liquid | IFCC recommended procedure | R1: 4 x 105 mL R2: 4 x 20 mL |
600 U/L | 340 |
AST/ SGOT Liqui-UV test | 2920-430 | Reagents | Liquid | IFCC recommended procedure | R1: 4 x 25 mL R2: 1 x 20 mL R3: 4 x 125 mL |
600 U/L | 340 |
AST/ SGOT Liqui-UV test | 2920-500 | Reagents | Liquid | IFCC recommended procedure | R1: 4 x 105 mL R2: 4 x 20 mL |
600 U/L | 340 |
ß-Hydroxybutyrate LiquiColor® test (Endpoint) | 2440-058 | Reagents | Liquid | β-Hydroxybutyrate dehydrogenase / INT | R1: 1 x 50 mL R2: 1 x 8.5 mL STD: 1 x 3 mL |
Up to 8 mmol/L* | 505 |
ß-Hydroxybutyrate LiquiColor® test (Beckman Synchron Cx/Lx/Dx) | B2440-180 | Reagents | Liquid | β-Hydroxybutyrate dehydrogenase / INT | 2 x 90 tests | Up to 8 mmol/L | 520 |
Bilirubin Total & Direct LiquiColor® test **This kit is a combination of refs. 0245-250 and 0240-080 | 0260-200 | Reagents | Liquid | Modified Walters-Gerarde | R1: 1 x 100 mL R2: 1 x 100 mL Oxidant: 1 x 15 mL Calibrator 1 x 6 mL |
10 mg/dL (direct) 20 mg/dL (total) |
540 |
Bilirubin Total LiquiColor® test | 0240-080 | Reagents | Liquid | Modified Walters-Gerarde | R1: 1 x 250 mL Oxidant: 1 x 15 mL Calibrator: 1 x 6 mL (10 mg/dL) |
20 mg/dL | 540 |
Bilirubin Total LiquiColor® test (DCa) |
0230-450 | Reagents | Liquid | DCA (2, 4-Dichloroaniline) | R1: 3 x 120 mL R2: 1 x 90 mL |
0.07 – 30 mg/dL | 540 |
Bilirubin Direct LiquiColor® Reagent | 0245-250 | Reagents | Liquid | Modified Walters-Gerarde | R1: 1 x 250 mL Oxidant: 1 x 15 mL |
10 mg/dL | 540 |
Bilirubin Direct LiquiColor® test (DCa) | 0235-450 | Reagents | Liquid | DCA (2, 4-Dichloroaniline) | R1: 3 x 120 mL R2: 1 x 90 mL |
0.1 – 10 mg/dL | 550 |
Calcium (Arsenazo) LiquiColor® test | 0155-225 | Reagents | Liquid | Arsenazo III | R1: 2 x 250 mL STD: 1 x 3 mL (10mg/dL) |
15 mg/dL | 650 |
Calcium (CPC) LiquiColor® test | 0150-250 | Reagents | Liquid | Cresolphthalein Complexone | R1: 1 x 125 mL R2: 1 x 125 mL STD: 1 x 3 mL (10 mg/dL) |
15 mg/dL | 550 |
Chloride LiquiColor® test | 0210-250 | Reagents | Liquid | Mercuric Thiocyanate | R: 1 x 250 mL STD: 1 x 3 mL (100 mEq/L) |
70 – 120 mEq/L | 500 |
Cholesterol LiquiColor® test (enzymatic) | 1010-225 | Reagents | Liquid | Modified Trinder | R: 2 x 250 mL STD: 1 x 3 mL (200 mg/dL) |
750 mg/dL | 500 |
Cholesterol LiquiColor® test (enzymatic) | 1010-430 | Reagents | Liquid | Modified Trinder | R: 4 x 30 mL STD: 1 x 3 mL (200 mg/dL) |
750 mg/dL | 500 |
CK Liqui-UV® test (Creatine Kinase/ UV-Rate ) |
2910-430 | Reagents | Liquid | Szasz modified reaction | R1: 4 x 24 mL R2: 4 x 6 mL |
1 – 1200 U/L | 340 |
Creatinine LiquiColor® test | 0430-120 | Reagents | Liquid | Enzymatic | R1: 3 x 30 mL R2: 1 x 30 mL |
30 mg/dL | 550 |
Creatinine LiquiColor® test | 0430-500 | Reagents | Liquid | Enzymatic | R1: 3 x 125 mL R2: 1 x 125 mL |
30 mg/dL | 550 |
Creatinine LiquiColor® test (Kinetic) |
0420-500 | Reagents | Liquid | Jaffe | R1: 1 x 250 mL R2: 1 x 250 mL STD: 1 x 5 mL (5 mg/dL) |
20 mg/dL | 510 |
HDL-Cholesterol test | 0599-020 | Reagents | Liquid | – | 1 x 20 mL | – | – |
HDL-Cholesterol direct LiquiColor® test | 0590-040 | Reagents | Liquid | Homogeneous method for direct HDL measurment | R1: 1 x 30 mL R2: 1 x 10 mL |
150 mg/dL | 600 |
HDL-Cholesterol direct LiquiColor® test | 0590-080 | Reagents | Liquid | Homogeneous method for direct HDL measurment | R1: 2 x 30 mL R2: 2 x 10 mL |
150 mg/dL | 600 |
HDL-Cholesterol direct LiquiColor® test | 0590-500 | Reagents | Liquid | Homogeneous method for direct HDL measurment | R1: 3 x 125 mL R2: 1 x 125 mL |
150 mg/dL | 600 |
Cholesterol, LDL direct LiquiColor® test | 0710-080 | Reagents | Liquid | Homogeneous method for direct LDL measurment | R1: 2 x 30 mL R2: 2 x 10 mL |
520 mg/dL | 600 |
Gamma-GT LiquiColor test (Rate) |
2960-430 | Reagents | Liquid | Modified Szasz | R1: 4 x 25 mL R2: 1 x 20 mL |
300 U/L | 405 |
Gamma-GT LiquiColor test (Rate) |
2960-500 | Reagents | Liquid | Modified Szasz | R1: 4 x 105 mL R2: 4 x 20 mL |
300 U/L | 405 |
Glucose LiquiColor® Reagent (enzymatic) |
1071-001 | Reagents | Liquid | Trinder | R: 1 x 1000 mL | 400 mg/dL | 500 |
Glucose LiquiColor® test (enzymatic) |
1070-125 | Reagents | Liquid | Trinder | R: 1 x 250 mL STD 1 x 3 mL (100 mg/dL) |
400 mg/dL | 500 |
Glucose LiquiColor® test (enzymatic) |
1070-500 | Reagents | Liquid | Trinder | R: 2 x 250 mL STD 1 x 3 mL (100 mg/dL) |
400 mg/dL | 500 |
Glucose Liqui-UV® test (Endpoint) |
1060-500 | Reagents | Liquid | Hexokinase | R1: 4 x 105 mL R2: 1 x 80 mL STD: 1 x 3 mL (100 mg/dL) |
500 mg/dL | 340 |
Glycohemoglobin direct (HbA1c) | 0360-040 | Reagents | Liquid | Turbidimetric immunoassay | R1: 1 x 30 mL R2: 1 x 10 mL R3 (lysing): 1 x 125 mL |
2 – 16% HbA1c | 600 |
Glycohemoglobin Pre-Fil test | P350-050 | Reagents | Liquid | Optimised Ion-exchange resin procedure | 50 tests STD: 1 x 1mL |
HbA1 4 – 20% HbA1c 2.6 – 16% |
415 |
Glycohemoglobin test (Hba1 and HbA1c) test |
0350-060 | Reagents | Liquid | Optimised Ion-exchange resin procedure | 60 tests STD: 1 x 1 mL |
HbA1 4 – 20% HbA1c 2.6 – 16% |
415 |
Iron & Total Iron Binding Capacity test |
0370-110 | Reagents | Liquid | Ferrozine | 110 tests R: 1 x 15 mL Buffer 1: 1 x 125 mL Buffer 2: 1 x 125 mL STD: 1 x 30 mL (500 mg/dL) |
1000 mg/dL | 560 |
LDH Liqui-UV® test (Rate) | 2940-430 | Reagents | Liquid | Modified wacker | R1: 4 x 25 mL R2: 1 x 20 mL |
800 U/L | 340 |
LDH Liqui-UV® test (Rate) | 2940-500 | Reagents | Liquid | Modified wacker | R1: 4 x 105 mL R2: 2 x 20 mL |
800 U/L | 340 |
Magnesium LiquiColor® test | 0130-430 | Reagents | Liquid | Xylidyl blue | R:4 x 30 mL STD: 1 x 3 mL (2 mEq/L) |
4.3 mEq/L | 520 |
Phosphorus Liqui-UV® test | 0830-125 | Reagents | Liquid | Phosphomolybdate | R: 1 x 250 mL STD: 1 x 3 mL (10 mg/dL) |
20 mg/dL | 340 |
Potassium test (Manual) | 0160-050 | Reagents | Liquid | Turbidimetric immunoassay | 50 test STD: 1 x 3 mL (4 mmol/L) |
10 mmol/L | 580 |
Salicylate Liqui-UV® test (Endpoint) |
2410-051 | Reagents | Liquid | Salicylate hydroxylase / NADH | R1: 1 x 50 mL R2: 1 x 1 mL STD: 1 x 3 mL (300 mg/L) |
1000 mg/L | 340 |
Sodium Test (Manual) | 0140-050 | Reagent | Liquid | Uranyl acetate | 50 tests STD: 1 x 6 mL (140 mmol/L) |
160 mmol/L | 420 |
Total Protein LiquiColor® test | 0250-500 | Reagents | Liquid | Biuret reaction | R: 2 x 250 mL STD: 1 x 3 mL (10 g/dL) |
10 g/dL | 550 |
Total Protein LiquiColor® test (CSF/ Urine) | 0345-212 | Reagents | Liquid | Pyrogallol red / Colorimetric | R: 1 x 250 mL STD: 1 x 3 mL (100 mg/dL) |
150 mg/dL | 600 |
Triglyceride LiquiColor® test (mono) |
2200-225 | Reagents | Liquid | Glycerylphosphate oxidase (GPO) | 2 x 250 mL STD: 1 x 2 mL (200 mg/dL) |
1000 mg/dL | 500 |
Triglyceride LiquiColor® test (mono) |
2200-430 | Reagents | Liquid | Glycerylphosphate oxidase (GPO) | R: 4 x 30 mL STD: 1 x 2 mL (200 mg/dL) |
1000 mg/dL | 500 |
Triglyeride LiquiColor® Reagent Set (enzymatic) | 2100-225 | Reagents | Liquid | Glycerylphosphate oxidase (GPO) | R1: 2 x 250 mL R2: 1 x 5.2 mL STD: 1 x 2 mL (200 mg/dL) |
1000 mg/dL | 500 |
Triglyeride LiquiColor® Reagent Set (enzymatic) | 2100-430 | Reagents | Liquid | Glycerylphosphate oxidase (GPO) | R1: 4 x 30 mL R2: 1 x 1.8 mL STD: 1 x 2 mL (200 mg/dL) |
1000 mg/dL | 500 |
Urea Nitrogen Liqui-UV® test (Rate) |
2020-430 | Reagents | Liquid | Modified urease | R1: 4 x 25 mL R2: 1 x 20 mL STD: 1 x 3 mL (30 mg/dL) |
140 mg/dL | 340 |
Urea Nitrogen Liqui-UV® test (Rate) |
2020-500 | Reagents | Liquid | Modified urease | R1: 4 x 105 mL R2: 4 x 20 mL STD: 1 x 3 mL (30 mg/dL) |
140 mg/dL | 340 |
Urea Nitrogen test | 0580-250 | Reagents | Liquid | Diacetylmonoxime | 250 tests STD 1: 1 x 3 mL (25 mg/dL) STD 2: 1 x 3 mL (50 mg/dL) STD3: 1 x 3 mL (75 mg/dL) |
980 mg/dL | 520 |
Uric acid LiquiColor® test (enzymatic) |
1045-225 | Reagents | Liquid | Trinder | 2 x 250 mL STD: 1 x 3 mL (8 mg/dL) |
20 mg/dL | 520 |
Uric acid LiquiColor® test (enzymatic) |
1045-430 | Reagents | Liquid | Trinder | R: 4 x 30 mL STD: 1 x 3 mL (8 mg/dL) |
20 mg/dL | 520 |
Cholesterol, Direct (HDL/ LDL) Calibrator | 0595-003 | Calibrators | Powder | Lyophilized human serum containing HDL and LDL | 1 x 3 mL | – | – |
Glycohemoglobin direct (HbA1c) Calibrators | 0365-401 | Calibrators | Powder | Requires reconstitution | 4 x 0.5 mL | – | – |
Ser-T-Cal Multi-Calibrator | 0550-605 | Calibrators | Powder | Lyophilized, requires reconstitution | 6 x 5 mL | – | – |
Glycohemoglobin (HbA1c) direct controls set | 0355-201 | Controls | Powder | Purified lipid hemolysate, requires reconstitution | 2 x 0.5 mL | – | – |
Glycohemoglobin bi-level controls | 0357-201 | Controls | Powder | Purified blood hemolysate, requires reconstitution | 2 x 1 mL | – | – |
Ser-T-Fy® Level 1 Control assayed serum | G427-86 | Controls | Powder | Lyophilized, requires reconstitution | 6 x 5 mL | – | – |
Ser-T-Fy® Level 2 Control assayed serum | G428-86 | Controls | Powder | Lyophilized, requires reconstitution | 6 x 5 mL | – | – |
ß-Hydroxybutyrate / TDM bi-level controls | 2465-605 | Controls | Liquid | Ready to use | 6 x 5 mL (3 low, 3 high level) | – | – |
ß-Hydroxybutyrate / TDM tri-level controls | 2460-605 | Controls | Liquid | Ready to use | 6 x 5 mL (2 low, 2 medium, 2 high level) | – | – |
Cholesterol Standard (200 mg/dL) | 1012-030 | Standards | Liquid | – | 1 x 30 mL | – | – |
Glucose Standard (100 mg/dL) | 1072-030 | Standards | Liquid | – | 1 x 30 mL | – | – |
ß-Hydroxybutyrate / TDM Linearity Standards | 2450-604 | Standards | Liquid | Liquid-ready-to-use | 6 x 4 mL | – | – |
*Application dependent